    Optically gated beating-heart imaging

    Get PDF
    The constant motion of the beating heart presents an obstacle to clear optical imaging, especially 3D imaging, in small animals where direct optical imaging would otherwise be possible. Gating techniques exploit the periodic motion of the heart to computationally "freeze" this movement and overcome motion artefacts. Optically gated imaging represents a recent development of this, where image analysis is used to synchronize acquisition with the heartbeat in a completely non-invasive manner. This article will explain the concept of optical gating, discuss a range of different implementation strategies and their strengths and weaknesses. Finally we will illustrate the usefulness of the technique by discussing applications where optical gating has facilitated novel biological findings by allowing 3D in vivo imaging of cardiac myocytes in their natural environment of the beating heart

    3D + time blood flow mapping using SPIM-microPIV in the developing zebrafish heart

    Get PDF
    We present SPIM-μPIV as a flow imaging system, capable of measuring in vivo flow information with 3D micron-scale resolution. Our system was validated using a phantom experiment consisting of a flow of beads in a 50 μm diameter FEP tube. Then, with the help of optical gating techniques, we obtained 3D + time flow fields throughout the full heartbeat in a ∼3 day old zebrafish larva using fluorescent red blood cells as tracer particles. From this we were able to recover 3D flow fields at 31 separate phases in the heartbeat. From our measurements of this specimen, we found the net pumped blood volume through the atrium to be 0.239 nL per beat. SPIM-μPIV enables high quality in vivo measurements of flow fields that will be valuable for studies of heart function and fluid-structure interaction in a range of small-animal models

    Multi-purpose SLM-light-sheet microscope

    Get PDF
    By integrating a phase-only Spatial Light Modulator (SLM) into the illumination arm of a cylindrical-lens-based Selective Plane Illumination Microscope (SPIM), we have created a versatile system able to deliver high quality images by operating in a wide variety of different imaging modalities. When placed in a Fourier plane, the SLM permits modulation of the microscope's light-sheet to implement imaging techniques such as structured illumination, tiling, pivoting, autofocusing and pencil beam scanning. Previous publications on dedicated microscope setups have shown how these techniques can deliver improved image quality by rejecting out-offocus light (structured illumination and pencil beam scanning), reducing shadowing (light-sheet pivoting), and obtaining a more uniform illumination by moving the highest-resolution region of the light-sheet across the imaging Field of View (tiling). Our SLM-SPIM configuration is easy to build and use, and has been designed to allow all of these techniques to be employed on one optical setup compatible with the OpenSPIM design. It also offers the possibility to choose between three different light-sheets, in thickness and height, which can be selected according to the characteristics of the sample and the imaging technique to be applied. We demonstrate the flexibility and performance of the system with results obtained by applying a variety of different imaging techniques on samples of fluorescent beads, Zebrafish embryos, and optically cleared whole mouse brain samples. Thus our approach allows easy implementation of advanced imaging techniques while retaining the simplicity of a cylindrical-lens-based light-sheet microscope

    Adaptive foveated single-pixel imaging with dynamic super-sampling

    Get PDF
    As an alternative to conventional multi-pixel cameras, single-pixel cameras enable images to be recorded using a single detector that measures the correlations between the scene and a set of patterns. However, to fully sample a scene in this way requires at least the same number of correlation measurements as there are pixels in the reconstructed image. Therefore single-pixel imaging systems typically exhibit low frame-rates. To mitigate this, a range of compressive sensing techniques have been developed which rely on a priori knowledge of the scene to reconstruct images from an under-sampled set of measurements. In this work we take a different approach and adopt a strategy inspired by the foveated vision systems found in the animal kingdom - a framework that exploits the spatio-temporal redundancy present in many dynamic scenes. In our single-pixel imaging system a high-resolution foveal region follows motion within the scene, but unlike a simple zoom, every frame delivers new spatial information from across the entire field-of-view. Using this approach we demonstrate a four-fold reduction in the time taken to record the detail of rapidly evolving features, whilst simultaneously accumulating detail of more slowly evolving regions over several consecutive frames. This tiered super-sampling technique enables the reconstruction of video streams in which both the resolution and the effective exposure-time spatially vary and adapt dynamically in response to the evolution of the scene. The methods described here can complement existing compressive sensing approaches and may be applied to enhance a variety of computational imagers that rely on sequential correlation measurements.Comment: 13 pages, 5 figure

    Feasibility of a trapped atom interferometer with accelerating optical traps

    Full text link
    In order to increase the measured phase of an atom interferometer and improve its sensitivity, researchers attempt to increase the enclosed space-time area using two methods: creating larger separations between the interferometer arms and having longer evolution times. However, increasing the evolution time reduces the bandwidth that can be sampled, whereas decreasing the evolution time worsens the sensitivity. In this paper, we attempt to address this by proposing a setup for high-bandwidth applications, with improved overall sensitivity. This is realized by accelerating and holding the atoms using optical dipole traps. We find that accelerations of up to 10310^{3}-10510^{5} m/s2^2 can be achieved using acousto-optic deflectors (AODs) to move the traps. By comparing the sensitivity of our approach to acceleration as a baseline to traditional atom interferometry, we find a substantial improvement to the state of the art. In the limit of appropriate beam and optics stabilization, sensitivities approaching 10−14^{-14} (m/s2^2)/Hz\sqrt{\rm Hz} may be achievable at 1 Hz, while detection at 1 kHz with a sensitivity an order of magnitude better than traditional free-fall atom interferometers is possible with today's systems.Comment: 25 pages. 9 figures. New subsection on achievable sensitivities added. Some corrections of factors of 2 and \pi. Numerics update
    • …